Stabl-Wall Reinforcing Fiber
| Parameter |
Minimum Value |
Governing Test Method |
| Tensile Strength |
500,000 psi |
ASTM D3039 |
| Tensile Strain |
1.5% |
ASTM D3039 |
| Tensile Modulus |
30,000,000 psi |
ASTM D3039 |
| Color |
Black |
None |
| Roll Width |
24 inches |
None |
| Roll Length |
270 feet |
None |
Stabl-Wall Adhesives: MINIMUM VALUES
| PARAMETER |
Stabl-Wall
Primer |
Stabl-Wall
Paste Filler |
Stabl-Wall
Bonding
Adhesive |
Governing
Test
Method |
Color
Part A
Part B
Mixed |
Amber
Clear
Amber |
Tan
Charcoal
Tan |
Amber
Clear
Amber |
None
None
None |
Mix Ratio (Volume)
Part A:Part B |
3:1 |
3:1 |
3:1 |
None |
Working Time @
70 F |
15 Minutes |
30 Minutes |
35 Minutes |
1 Gallon
Sample |
| Shelf Life |
12 Months |
12 Months |
12 Months |
None |
| Tensile Strength |
2,000 psi |
2,000 psi |
7,000 psi |
ASTM D638 |
| Tensile Strain |
0.30 |
0.05 |
0.03 |
ASTM D638 |
| Tensile Modulus |
100,000 psi |
230,000 psi |
400,000 psi |
ASTM D638 |
An engineers and surveyors report from Kenneth Jensen & Associates, Inc. on the feasibility of using carbonfiber polymer sheets on cracked residental foundation walls is available by request. This report wasprepared specifically for the Stabl-Wall product.
|